D.T. Fantoni; A.M. Ambrósio; D.M. Sakai; J. Krumenerl; J. Lolli Jr; A.R.C. Martins; R. Benedetto; A.H. Oshiro
Introduction
PaO2/FiO2 ratio is the marker of hypoxemia according to the American-European Consensus Conference on lung injury. A high FiO2 level has been reported to variably alter PaO2/FiO2 (Allardet-Servent et al 2009). Adequate blood oxygenation may be difficult to be achieved, even when lungs are ventilated with high O2 mixtures. In human beings, inspiration of 100% oxygen during anesthesia promotes intra-pulmonary shunt and atelectasis, in contrast to the inspiration of 30% oxygen in nitrogen (Magnusson & Spahn 2003; Marntell et al 2005). Little attention has been paid to the effect of different fractional inspired oxygen concentration (FiO2) on arterial oxygenation in dogs. Oxygen causes tissue injury through formation of reactive oxygen intermediates that cause lipid peroxidation, direct DNA damage and protein sulfhydryl oxidation. Until now, it is not known how an exposure to unnecessary high oxygen mixtures can trigger this complex metabolic cascade, especially in those individuals with decreased antioxidant defenses, who are highly susceptible to oxidative stress. The main issue is not related to the use of 100% oxygen, but also to any amount of oxygen that is not necessary. For example, resuscitation of piglets for only 15 min with just 40 or 60% oxygen causes increased oxidative stress and dosedependent oxidation of DNA and phenylalanine (Sola 2008).The aim of the present study was to compare the effects of different FiO2 (40, 60, 80 and 100%) on the PaO2/FiO2 ratio during mechanical ventilation in anesthetized dogs.
Material and Methods
After approval of the Ethics Committee of the Veterinary Hospital of The Faculty of Veterinary Medicine of the University of Sao Paulo, 24 dogs of different breeds and ages, weighing from 10 to 20kg undergoing elective surgery lasting from 2 to 3 hours were evaluated. All animals included in this experiment were ASA I and II based in clinical examinations and laboratory tests. Pre-anesthetic medication was acepromazine (0,05 mg.kg-1) associated with meperidine (2 mg.kg-1) administered intramuscularly. Anesthesia was induced with 5 mg.kg-1 of intravenous propofol and orotracheal intubation was then performed using a cuffed endotracheal tube. General anesthesia was maintained with 1,4% end-tidal concentration of isoflurane and dogs were mechanically ventilated with intermittent positive-pressure ventilation (IPPV) with a tidal volume of 10 ml/kg, no positive end-expiratory pressure (ZEEP); respiratory frequency was adjusted in order to maintain end-tidal carbon dioxide tension (PETCO2) between 35-45 mmHg. Intravenous fluid administration used consisted in 10 ml. kg-1 hour-1 lactated Ringer solution. Dogs were randomized into four groups of 6 animals each (n = 6). Group I (G40) was maintained with an expired oxygen fraction (FiO2) of 40%; group II (G60) with a FiO2 of 60%; group III (G80) with a FiO2 of 80% and group IV (G100) 100% of FiO2. Arterial blood samples were collected from a catheter inserted in the femoral artery in three different moments in order to obtain the arterial partial pressure of oxygen (PaO2). The first sample was collected 10 minutes after pre-anesthetic medication; the second sample 10 minutes after stabilization of general anesthesia and the third sample was collected 10 minutes after extubation. The PaO2/FiO2 ratio was then evaluated and compared among different moments and groups. Parametric values were analyzed by using one-way analysis of variance (ANOVA). Tukey test was used to analyze differences among groups. P values < 0,05 were considered significant.
Results
There were no statistical differences among groups receiving different inspired oxygen concentrations (FiO2) nor among moments. PaO2/FiO2 ratios were similar despite of the FiO2. Data shown on table 1 demonstrates the behavior of this variable. The ratio was lower in G40 after stabilization of anesthesia (372±96), but statistically there was no difference from the basal value (M1) and also no difference among groups receiving higher O2 mixtures. G100 animals had slightly higher ratio values in all moments of the experiment.
Table 1. PaO2/FiO2 ratios.
Group
|
M1
|
M2
|
M3
|
G40
|
441±103
|
372±96
|
403±105
|
G60
|
415±65
|
447±39
|
465±46
|
G80
|
426±22
|
436±57
|
468±61
|
G100
|
441±18
|
465±95
|
475±37
|
Data presented as mean ±SD. M1 = 10 minutes after pre-anesthetic medication. M2 = 10 minutes after stabilization of anesthesia. M3 = 10 minutes after extubation. Numbers shown in the group column represent the inspired fraction of oxygen (i.e., G40 = 40% of FiO2)
Discussion and Conclusions
According to our study the use of different inspired fractions of oxygen resulted in similar values of PaO2/FiO2, which means that maintaining lower FiO2 levels (40%, for instance) during mechanical ventilation in dogs didn't cause hypoxemia. It is known that high O2 mixtures can be harmful for the patient, since it may cause intra-pulmonary shunt and atelectasis as well as tissue injury through formation of reactive oxygen intermediates that cause lipid peroxidation, direct DNA damage and protein sulfhydryl oxidation. For these reasons the use of lower FiO2 in order to prevent the "side effects" of oxygen would be interesting, as long as it didn't compromise oxygenation. Although G40 had lower PaO2/FiO2, it was statistically and physiologically similar to all other groups. In conclusion, the use of lower FiO2 during mechanical ventilation in anesthetized dogs didn't cause hypoxemia and had similar values of oxygenation when compared with groups with higher O2 mixtures.
References
1. Allerdet-Servent J, Forel JM, Roch A, Guervilly C, Chiche L, Castanier M, Embriaco N, Gainnier M, Papazian L. 2009. FiO2 and acute respiratory distress syndrome definition during lung protective ventilation. Crit Care Med 37(1): 202-7.
2. Magnusson L, Spahn DR. 2003. New concepts of atelectasis during general anesthesia. Br J Anaesth 91(1): 61-72.
3. Marntell S, Nyman G, Hedenstierna G. 2005. High inspired oxygen concentrations increase intrapulmonary shunt in anaesthetized horses. Vet Anaesth Analg 32(6):338-47.
4. Sola A. 2008. Oxygen in neonatal anesthesia: friend or foe? Curr Opin Anaesthesiol 21: 332-339.